ICYaLata t1_j6pi19f wrote

The GFI will protect your equipment by killing power if any voltage leaks to ground. The ground wire is just an alternative patch back to the main board bonded to the neutral. Thus its not "grounded", but will be disconnected in the event any leak to ground is detected.

1

ICYaLata t1_j6b2c1z wrote

Ground wire is not the problem. Switch should only control the Hot wire.
1)Do you have 120v at the line side of your switch?
2)Do you have 120v on the load side of the switch when it's on? 3)Do you have continuity of the hot conductor from switch to your fixture? 4)Are you sure your fixture works? 5) are all your connections secure and properly done?

1

ICYaLata t1_j5bkp4g wrote

Glass and plastic is most likely one assembly. The whole thing will pull down with metal spring clips holding it up. If it's been there a while, might have to get something thin to work around the edges and break it free.

3

ICYaLata t1_j1z1eqb wrote

I use a couple 120v computer style fans plugged into a 12v activated relay plug strip. When my audio receiver is turned on, it turns the fans on. Can also put them on a traditional resistive dimmer to slow them down for noise if needed.

1

ICYaLata t1_j1xr026 wrote

You can split wire an outlet. There are metal tabs you break off. Take a circuit to a switch. Tap the circuit with one constant hot(black) and one thru the switch (red). Run 3wire to your outlets. Wire half the outlet to the red and half to the black. Youll then have outlets that are "split wired" and half will be switched and the other half constant.

1

ICYaLata t1_j1xqde0 wrote

Decora style. Also run coax and ethernet to each room from a single location while you have the opportunity. Multiple if the room is able to be set up multiple ways. Outlets should be every 12' along the walls. I also like to add half switched outlets even if you go permanently installed overhead lights and a fan. While you are at it, interconnected 120v smoke detectors (assuming you are in USA) run them off a circuit connected to often used lighting.

1

ICYaLata t1_ixwckri wrote

Don't worry about the gaps. Your finish floor will cover those up. Find where the squeaks are and use some screws and sink them thru the boards into the joists. Even if you find them all now, new ones will show up when the weather changes, just keep that in mind.

10

ICYaLata t1_ixdouqb wrote

Do you have both hor and cold water lines hooked up? If only cold, are you washing cold/cold? Washer might be assuming it's getting warm water also and cutting flow from the cold. Just a thought.