darkwing79
darkwing79 t1_jdt09ws wrote
Reply to comment by work_blocked_destiny in Need help with smart switch wiring by work_blocked_destiny
Yes, wire back to the panel, wire to the switch, wire to the smart switch and wire to the load. Put all 4 together twist them with together with a pair of pliers and stick a wire nut on them.
darkwing79 t1_jdszqb0 wrote
If that is the neutral floor the light it will need to be connected to the same neutral that is connected to N and the switch
darkwing79 t1_jdsxj0w wrote
Disconnect the hot from your switch, connect it to the L portion of the smart switch. Put 2 pigtails on the neutral, connect one neutral to the N on the smart switch. Connect second neutral to your switch. Connect switch to S1 and then connect your load (lightbulb) to L1
darkwing79 t1_jdt28ax wrote
Reply to comment by work_blocked_destiny in Need help with smart switch wiring by work_blocked_destiny
No problem, just remember to be careful and always double check the wiring. Be safe.